image of Temprecord data loogers available from CalX Instrumentation Services

Temprecord Data Loggers - Accurate, Precise, Reliable.

Temprecord data loggers are recognised globally for their degree of accuracy, precision, and reliability. Calibration corrections are built into each calibrated logger, meaning there is no need for the user to add a correction formula to the downloaded data, reducing the potential for error or omission altogether. Temprecord data loggers are used in numerous sectors including laboratories, hospitals, blood services, food processing, industrial and logistics companies.

Accredited to ISO 17025 Calibration Laboratory Standard.

For more info or to order call or email the CalX sales team or fill out our contact form.

G4 Display ISO 17025 Calibrated Data Loggers

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard.

Case Range: -50 °C to +75 °C ( -58 °F to +167 °F )

Accuracy: Calibrated Range ± 0.2°C ( 0.35°F )

Probe Range: -90 °C to +110 °C ( -130 °F to +230 °F )

Memory: 32k / 32511 samples

Warranty: 24 months

Waterproof: IP67 or NEMA 6

Battery: 24 months

Calibration: 24 months

Data Resolution: 0.01 °C / 0.01 °F

LED: Indicate if within/outside of set limits

Button: Start/Stop/Mark

Free software automatically calculates MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)

Traceable Calibration Certificate included.

G4 Medical Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard.

Case Range: -50 °C to +75 °C ( -58 °F to +167 °F )

Accuracy: Calibrated Range ± 0.2°C ( 0.35°F )

Probe Range: Probe not available on Medical Logger. See Scientific logger for probe version

Memory: 32k / 32511 samples

Warranty: 24 months

Waterproof: IP67 or NEMA 6

Battery: 24 months

Calibration: 24 months

Data Resolution: 0.01 °C / 0.01 °F

LED: Indicate if within/outside of set limits

Button: Start/Stop/Mark

Free software includes built in statistics.

Traceable Calibration Certificate included.

G4 SuperCool & Dry Ice Data Logger

Low temperature monitoring when product integrity is critical. Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard

Case Range: -50 °C to +75 °C ( -58 °F to +167 °F )

Accuracy: Calibrated Range ± 0.2°C ( 0.35°F )

Probe Range: -90 °C to +110 °C ( -130 °F to +230 °F )

Memory: 8k / 7935 samples

Warranty: 12 months

Waterproof: IP67 or NEMA 6

Battery: 24 months

Data Resolution: 0.01 °C / 0.01 °F

LED: Indicate if within/outside of set limits

Button: Start/Stop/Mark

Free software automatically calculates: MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)

Traceable Calibration Certificate included.

G4 Multitrip Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard

Case Range: -25 °C to +60 °C ( -13 °F to +140 °F )

Accuracy: Calibrated Range ± 0.2°C ( 0.35°F )

Probe Range: -50 °C to +110 °C ( -58 °F to +230 °F )

Memory: 8k / 7935 samples

Warranty: 12 months

Waterproof: IP67 or NEMA 6

Battery: 24 months

Data Resolution: 0.01 °C / 0.01 °F

LED: Indicate if within/outside of set limits

Button: Start/Stop/Mark

Free software automatically calculates: MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)

Traceable Calibration Certificate included.

G4 Cryogenic Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard

Case Range: – 50 °C to +75 °C ( -58 °F to +167 °F )

Accuracy: Calibrated Range ± 1°C ( 1.8°F )

Probe Range: -200 °C to 0 °C ( -328 °F to +32 °F )

Memory: 32k / 32511 samples

Warranty: 12 months

Waterproof: IP67 or NEMA 6

Battery: 24 months

Data Resolution: 0.01 °C / 0.01 °F

LED: Indicate if within/outside of set limits

Button: Start/Stop/Mark

Free software automatically calculates: MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)

Traceable Calibration Certificate included.

G4 RH Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard.

Case Range: -25 °C to +60 °C ( -13 °F to +140 °F )

Accuracy: Calibrated Range ± 0.2°C ( 0.35°F )

Probe Range:  -50 °C to +110 °C ( -58 °F to +230 °F )

Memory: 16k RH samples 16k Temperature samples

Warranty: 12 months

Splashproof: IP56 or NEMA 4X

Battery: 24 months

Data Resolution: 0.01 °C / 0.01 °F

LED: Indicate if within/outside of set limits

Button: Start/Stop/Mark

Free software automatically calculates: MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)

Traceable Calibration Certificate included

Scientific Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard.

Case Range: -50 °C to +60 °C ( -58 °F to +140 °F )

Accuracy: Calibrated Range ± 0.2°C ( 0.35°F )

Probe Range: -80 °C to +110 °C ( -112 °F to +230 °F )

Memory: 32k / 32000 samples

Warranty: 24 months

Battery: 24 months

Waterproof: IP67 or NEMA 6

Data Resolution: 0.01 °C / 0.01 °F

LED: Indicate if within/outside of set limits

Button: Start/Stop/Mark

Free software automatically calculates: MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)

Traceable Calibration Certificate included.

Low Temp Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard.

Case Range: -50 °C to +60 °C ( -58 °F to +140 °F )

Accuracy: Calibrated Range ± 0.2°C ( 0.35°F )

Probe Range: -50 °C to +110 °C ( -58°F to +230°F )

Memory: 8k / 7935 samples

Warranty: 12 months

Battery: 24 months

Waterproof: IP67 or NEMA 6

Data Resolution: 0.01 °C / 0.01 °F

LED: Indicate if within/outside of set limits

Button: Start/Stop/Mark

Free software automatically calculates: MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)

Traceable Calibration Certificate included.

Supercool Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard.

Case Range: -50 °C to +60 °C ( -58 °F to +140 °F )

Accuracy: Calibrated Range ± 0.2°C ( 0.35°F )

Probe Range: -80 °C to +110 °C ( -112 °F to +230 °F )

Memory: 8k / 7935 samples

Warranty: 12 months

Waterproof: IP67 or NEMA 6

Battery: 24 months

Data Resolution: 0.01 °C / 0.01 °F

LED: Indicate if within/outside of set limits

Button: Start/Stop/Mark

Free software automatically calculates: MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)

Traceable Calibration Certificate included.

Medical Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard.

Case Range: -50 °C to +60 °C ( -58 °F to +140 °F )

Accuracy: Calibrated Range ± 0.2°C ( 0.35°F )

Memory: 32k / 32511 samples

Warranty: 12 months

Battery: 24 months

Waterproof: IP67 or NEMA 6

Data Resolution: 0.01 °C / 0.01 °F

LED: Indicate if within/outside of set limits

Button: Start/Stop/Mark

Free software automatically calculates: MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)

Traceable Calibration Certificate included.

RH Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard.

Case Range: -25 °C to +60 °C ( -13 °F to + 140 °F ) 0 %RH to 100 %RH

Accuracy: Calibrated Range : ± 0.2°C ( 0.35°F ) Humidity Range : ± 3%

Memory: 32k / 32511 samples

Warranty: 12 months

Battery: 24 months

Waterproof: IP67 or NEMA 6

Data Resolution: 0.01 °C / 0.01 °F

LED: Indicate if within/outside of set limits

Button: Start/Stop/Mark

Free software automatically calculates: MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)

Certificate included.

Econolog Data Logger

Case Range: -25 °C to +60 °C ( -13 °F to + 140 °F ) 0 %RH to 100 %RH

Accuracy: Case Range : 0.5 °C (1 °F )

Memory: 8k / 7985 samples

Warranty: 12 months

Battery: 24 months

Waterproof: IP67 or NEMA 6

Data Resolution: 0.01 °C / 0.01 °F

LED: Indicate if within/outside of set limits

Button: Start/Stop/Mark

Free software automatically calculates: MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)

Statement of Accuracy Certificate Available on Request.

Multitrip Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard.

Case Range: -25 °C to +60 °C ( -13 °F to + 140 °F ) 0 %RH to 100 %RH

Accuracy: Calibrated Range ± 0.2°C ( 0.35°F )

Probe Range: -50 °C to +110 °C ( -58 °F to +230 °F )

Memory: 8k / 7935 samples

Warranty: 12 months

Battery: 24 months

Waterproof: IP67 or NEMA 6

Data Resolution: 0.01 °C / 0.01 °F

LED: Indicate if within/outside of set limits

Button: Start/Stop/Mark

Free software automatically calculates: MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)

Traceable Calibration Certificate included.

Mon T2

Low cost

Case Range: -30 °C to +60 °C ( -22 °F to +140 °F )

Accuracy: Case Range : 0.5°C (1 °F )

Memory: 16k / 16384 samples

Warranty: 12 months or 200,000 samples

Waterproof: IP67 or NEMA 6

Display Resolution: 0.01 °C / 0.01 °F

LED: Indicates out of range

Button: Start/Stop/Status/Tag/ReUse

Mon-T2 LCD

Low cost

Case Range: -30 °C to +60 °C ( -22 °F to +140 °F )

Accuracy: Case Range : 0.5°C (1 °F )

Memory: 16k / 16384 samples

Warranty: 12 months or 200,000 samples

Waterproof: IP67 or NEMA 6

Display Resolution: 0.01 °C / 0.01 °F

LED: Indicates out of range

Button: Start/Stop/Status/Tag/ReUse

LCD: Shows Min, Max and Average and can be extended to show Time Above and Below Limit

Mon-T2 USB

Low cost

Case Range: -30 °C to +60 °C ( -22 °F to +140 °F )

Accuracy: Case Range 0.5°C (1 °F )

Memory: 16k / 16384 samples

Warranty: 12 months or 200,000 samples

Waterproof: IP67 or NEMA 6

Display Resolution: 0.01 °C / 0.01 °F

LED: Indicates out of range

Button: Start/Stop/Status/Tag/ReUse

No special reader required.

Mon-T2 LCD USB

Low cost

Case Range: -30 °C to +60 °C ( -22 °F to +140 °F )

Accuracy: Case Range 0.5°C (1 °F )

Memory: 16k / 16384 samples

Warranty: 12 months or 200,000 samples

Waterproof: IP67 or NEMA 6

Display Resolution: 0.01 °C / 0.01 °F

LED: Indicates out of range

Button: Start/Stop/Status/Tag/ReUse

LCD: Shows Min, Max and Average and can be extended to show Time Above and Below Limit

No special reader required.

Mon-T2 RH

Low cost

Case Range: -30 °C to +60 °C ( -22 °F to +140 °F ) 5 %RH to 95 %RH​

Accuracy: Case Range 0.5°C (1 °F ) Humidity Range 3 % RH

Memory: 16k / 16384 samples

Warranty: 12 months or 200,000 samples

Waterproof: IP67 or NEMA 6

Display Resolution: 0.01 °C / 0.01 °F

LED: Indicates out of range

Button: Start/Stop/Status/Tag/ReUse

Mon-T2 LCD RH

Low cost

Case Range: -30 °C to +60 °C ( -22 °F to +140 °F ) 5 %RH to 95 %RH​

Accuracy: Case Range 0.5°C (1 °F ) Humidity Range 3 % RH

Memory: 16k / 16384 samples

Warranty: 12 months or 200,000 samples

Splash proof: DA approved food grade casing

Display Resolution: 0.01 °C / 0.01 °F

LED: Indicates out of range

Button: Start/Stop/Status/Tag/ReUse

LCD: Shows Min, Max and Average and can be extended to show Time Above and Below Limit.

 

Mon-T2 RH USB

Low cost

Case Range: -30 °C to +60 °C ( -22 °F to +140 °F ) 5 %RH to 95 %RH​

Accuracy: Case Range 0.5°C (1 °F ) Humidity Range 3 % RH

Memory: 16k / 16384 samples

Warranty: 12 months or 200,000 samples

Splash proof: DA approved food grade casing

Display Resolution: 0.01 °C / 0.01 °F

LED: Indicates out of range

Button: Start/Stop/Status/Tag/ReUse

No special reader required.

Mon-T2 LCD RH USB

Low cost

Case Range: -30 °C to +60 °C ( -22 °F to +140 °F ) 5 %RH to 95 %RH​

Accuracy: Case Range 0.5°C (1 °F ) Humidity Range 3 % RH

Memory: 16k / 16384 samples

Warranty: 12 months or 200,000 samples

Waterproof: IP67 or NEMA 6

Display Resolution: 0.01 °C / 0.01 °F

LED: Indicates out of range

Button: Start/Stop/Status/Tag/ReUse

LCD: Shows Min, Max and Average and can be extended to show Time Above and Below Limit.

No special reader required.

Mon-T2 DRY ICE LCD USB

Low cost

Probe Range: -90 °C to +40 °C ( -130 °F to +104 °F )

Accuracy: Operating Range 1°C (1.8 °F )

Memory: 16k / 16384 samples

Warranty: 12 months or 200,000 samples

Waterproof: Splash proof

Display Resolution: 0.01 °C / 0.01 °F

LED: Indicates out of range

Button: Start/Stop/Status/Tag/ReUse

LCD: Shows Min, Max and Average and can be extended to show Time Above and Below Limit

Case Rangeis limited to -30 °C and must be left outside of the dry ice environment.

No special reader required.

Mon-T2 Mini PDF

Low Cost Single-Use

Case Range: -30 °C to +60 °C

Accuracy: Case Range 0.5°C

Memory: 8k / 8192 samples

Warranty: 1 Trip or 12 months shelf life from date of manufacture

Waterproof: IP67 or NEMA 6

Display Resolution: 0.01 °C / 0.01 °F

LED: Status Indicators

Button: Start/Stop/Status/Tag

USB Connector Easily download data.

No special reader required.

Mon-T2 Mini PDF NFC

Low Cost Single-Use

Case Range: -30 °C to +60 °C

Accuracy: Case Range 0.5°C

Memory: 8k / 8192 samples

Warranty: 1 Trip or 12 months shelf life from date of manufacture

Waterproof: IP67 or NEMA 6

Display Resolution: 0.01 °C / 0.01 °F

LED: indicates out of range

Button: Start/Stop/Status/Tag

LCD: Shows Min, Max, Average, Time Above and Time Below Limit

No special reader required.

Mon-T2 Mini PDF NFC LCD

Low Cost Single-Use

Case Range: -30 °C to +60 °C

Accuracy: Case Range 0.5°C

Memory: 8k / 8192 samples

Warranty: 1 Trip or 12 months shelf life from date of manufacture

Waterproof: IP67 or NEMA 6

Display Resolution: 0.01 °C / 0.01 °F

LED: Status Indicators

Button: Start/Stop/Status/Tag

LCD: Shows Min, Max, Average, Time Above and Time Below Limit

NFC: Near Field Communication

No special reader required.

Back to Top

Data Logger Holder

Used for securing Temprecord Data Loggers onto required surface.

  • Strong, durable and waterproof polycarbonate.
  • Logger LED limit indicator lights easily visible.
  • Easy to secure onto chosen surface.
  • Custom-made for Temprecord loggers.
  • Material will not discolour.
  • Can be attached with counter sunk screws (included).
  • Adhesive Velcro strips and double sided tape may also be used.

Temprecord Data Logger Reader

Temprecord for Windows Software utilises our innovative Temprecord Reader Interface device that can be used with USB connections. The Reader Interface allows users to download, analyse and program a Temprecord data logger.

  • One reader for all loggers; old and new models.
  • USB.
  • Start, stop, reuse or program data logger using TRW software.
  • Optical reader feature – no physical connection to Data Logger.
  • Temprecord for Windows (TRW) Software is freely available for download on this website.
  • Compatible with Windows 7, 8 & 10.
  • Reliable long life product. Warranty Period: 12 months from date of purchase.
  • IP 40 water rated protection.

Mon-T2 Mini PDF NFC LCD

The Mon-T Mini USB cable is essential for downloading data from your Temprecord Mon-T Data Logger.

  • 1 metre length mini USB cable.
  • For use on the Temprecord Mon-T USB Data Logger.

 

Back to Top

TAD (Temprecord Active Display) - Real Time Monitoring

TAD Real-time Temperature Monitoring available from CalX.

For more info or to order call or email the CalX sales team or fill out our contact form.

Temprecord Active Display (TAD) is a revolutionary real-time temperature and humidity monitoring system from Temprecord International. At the heart of TAD is Temprecord’s Scientific multi-use recorder – calibrated and supplied with a traceable calibration certificate to international ISO/IEC 17025 standard.

Great for compliance and risk management, TAD features include:

  • User programmed alarm preferences
  • Continues to log during power or network failure
  • Monitoring and reporting options
  • Step-down alarm features and options
  • Fail-safe backup and lost data refresh
  • ISO17025 standard and effortless recalibration programme
  • Hardware options for mobility
  • Save money by automating monitoring functions and alerts therefore preserving valuable product before it goes out of acceptable environmental limits during:
  • Storage
  • Manufacturing/processing

Temprecord Active Display (TAD) Real-time Monitoring  is an automated “hands off” system that monitors environmental information as it happens, then sends out a warning enabling action to be taken in a timely manner to preserve valuable products.  Fully automated monitoring, warning and reporting system requiring minimal human input, saving time and money as well as reducing the potential for human error.

Monitor temperature, humidity, CO2, room pressure differential,  power fail, door open, all in real time

Each unit can be individually programmed for parameters, alerts, reports, etc

Regular automatic reports to QA Management in PDF format, with critical data backup

100% reliable – in the event of power failure TAD data loggers continue to log and the data is later automatically extracted to complete the TAD reports, i.e., no data is lost.  This has been a huge advantage for our customers with critical products when correlating data has been unavailable.

Portable – The monitoring hardware can be moved easily with cabinets as required.

Each TAD system will support 240 probes.  If requiring more than 240 probes then multiple TAD systems can be run, linking with each other via remote access.

TAD Software is “Hands off” automated system which is easy to use, but comprehensive.  All channels are easily configurable for individual parameters and alert recipients.  Temprecord will pre program with client requirements if provided.  Training is provided with new installations.  All Temprecord software is free.

Calibrations are built into the TAD temperature and humidity loggers. No requirement for a correction formula to be applied to the downloaded data after recalibration, therefore potential for human error is removed.  Data is available with 0.01°C display resolution.

Accuracy across stated range:

Temperature: 0.2 °C / 0.35 °F or better.

Humidity: 3%

CO2: +/- 1.5% of range + 2% of reading

Room Pressure Differential:  0.02 of a Pa.  The sensors have zero drift and are offset free.

Monitoring Range

Temperature:

  • Standard – see individual logger specifications
  • Low Temperature -80 °C / -112 °F
  • Cryogenic -196 °C / -320 °F
  • High Temperature 250 °C / 480 °F

 

Humidity: 0 – 100%

CO2: 2% ,3%, 5%, 10%, or 20%

Room Pressure Differential: -100 to +100 Pa

TAD Real-time Temperature Monitoring 